Replacing an existing hob
Compare the cut-out and the space beneath the worktop with the dimensions required for the new installation. Que Choisir Ensemble highlights the importance of dimensions when replacing a standard hob.
If you’re replacing a hob and don’t have a wall-mounted extractor, consider a venting hob if your cabinet can accommodate its unit and the air route specified in the instructions. Que Choisir Ensemble says extraction works better than recirculation, but it requires a usable outlet. Without an outlet to the outside, recirculation means you’ll need to maintain the filters. It doesn’t replace ventilation in your home: the order of 24 March 1982 requires air outlets in service rooms, including the kitchen, subject to the conditions set out in the legislation.
Compare the cut-out and the space beneath the worktop with the dimensions required for the new installation. Que Choisir Ensemble highlights the importance of dimensions when replacing a standard hob.
You want to cook without a wall-mounted extractor and need to allow space for the recirculation system, as well as access to the filters. Que Choisir Ensemble describes recirculation as an option when extraction isn’t possible.
You may be able to install an outlet to the outside, but check the duct route and the rules that apply to your home before choosing this option.
Your choice of mode depends first on whether an air outlet is available and how much space there really is beneath the worktop. Que Choisir Ensemble distinguishes between extraction and recirculation; the installation must also follow the product instructions and maintain ventilation in your home.
Consider this if: there’s a usable outlet and the unit and ducts can fit beneath the worktop.
Bear in mind: Que Choisir Ensemble says extraction works better than recirculation, but the route must be practical. Article 14 of the order of 24 March 1982 prohibits connecting an individual mechanical device to a shared air outlet.
Consider this if: there’s no outlet to the outside and your cabinet allows for the return air route and access to the filters.
Bear in mind: filtered air is returned to the room. Recirculation doesn’t vent cooking moisture outside, and the filters need maintaining.
Consider this if: the extractor unit can’t be fitted beneath the worktop, or you’d prefer two separate appliances.
Bear in mind: an extractor above the hob won’t free up this space. A worktop extractor also needs room and careful installation planning.
| What to consider | What to check before buying | Who this matters most to |
|---|---|---|
| Dimensions and fit beneath the worktop | Measure the cut-out, the cabinet’s internal dimensions and the space taken up by drawers; compare these measurements with the model’s installation plan. | If I’m replacing a hob, I want to keep the worktop and cabinet without needing unexpected alterations. Around 33% of consumers prioritise fitting dimensions. |
| Air route and extraction mode | Check for an outlet to the outside and plan the duct route. For recirculation, check the return air route specified in the instructions. Que Choisir Ensemble distinguishes between the two modes according to the installation. | If I’m unsure about the air outlet, I want to know which system can realistically be fitted in my home. Around 27% of consumers prioritise a workable air route. |
| Access to filters and maintenance | Find out which filter is compatible and whether it can be cleaned or needs replacing, then check its instructions and price. | If I choose recirculation, I want to be able to access the filters and plan for their maintenance. Around 20% of consumers put ease of maintenance first. |
| Electrical installation and household regulations | Check the circuit against the model’s instructions and have the installation inspected. Find out whether the available extraction system is individual or shared. Bosch recommends professional installation for its induction hobs. | If I’m renovating, I want the connection checked and to avoid a project that doesn’t comply with the rules for my home. Around 20% of consumers prioritise preparing the work and ensuring the installation meets requirements. |
When replacing a hob, the existing cut-out and the space beneath the worktop can matter just as much as the visible width of the hob.
Measure the cut-out and cabinet, then compare them with the model’s installation plan before ordering.
Not all carbon filters have the same care instructions: some are single-use, while others can be cleaned, according to Electrolux.
Check which filter is compatible, how to maintain it and what the instructions say for the model you’re considering.
Article 14 of the order of 24 March 1982 prohibits connecting an individual mechanical device to a shared air outlet system, whether mechanical or natural-draught.
Have the duct identified before choosing extraction, and don’t plan to connect it to a shared extraction system.
These induction hobs combine cooking and extraction in one appliance. Their inclusion in this selection doesn’t confirm that they’ll fit your cabinet: check the dimensions, connections and installation instructions for each model.
Image unavailable
Worth considering if you want to combine an induction hob and integrated extraction in one appliance.
Four cooking zones. Stated cut-out: 560 × 490 mm. Stated power supply: 32 A, 220–240 V; professional installation specified.
CBEHKIT installation accessories are required and sold separately. Check the dimensions and electrical requirements against your kitchen before buying.
Image unavailable
Worth considering if you’re looking for an induction hob with an integrated extractor and a stated width of 80 cm.
Four cooking zones and Bridge function. Removable, washable filter. Stated two-phase connection: 7,6 kW; professional installation specified.
Check the cut-out, the space available beneath the worktop and the connection requirements against the model’s instructions.
No. It filters the air and returns it to the room; it doesn’t replace ventilation in your home. The order of 24 March 1982 requires air outlets in service rooms, including the kitchen, subject to the conditions set out in the legislation. Make sure you preserve the ventilation system during renovation work.
No. Article 14 of the order of 24 March 1982 prohibits connecting an individual mechanical device, such as an extractor with a fan, to a shared air outlet system, whether mechanical or natural-draught. Have the duct identified before planning the installation.
It depends on the filter and its instructions: some carbon filters are disposable, while others can be cleaned. Electrolux gives 160 hours of use as a general recommendation for its cooker hoods; this isn’t a universal guideline for venting hobs.
Yes. Have the existing power supply checked against the instructions for the model you choose, rather than assuming the old hob’s circuit will be suitable. Bosch recommends professional installation for its induction hobs.
The cost depends on the filter type and the product’s maintenance requirements. Before working out your budget, check the price and availability of the filter, as well as the care instructions for the model you’re considering.